nVent Raychem Commercial & Residential Solutions

 

nVent RAYCHEM Has Self-Regulating Heating & Freeze Protection Systems

The winter’s ice, snow, and freezing temperatures can wreak havoc on homes and the people living in them. Taking proper steps to prepare your property for the cold weather can help you avoid possible costly problems. These damages can include water damage due to frozen pipes, roof damage caused by ice dams, or medical costs/vehicle accidents due to slippery paths.

nVent for Commercial Solutions: nVent RAYCHEM offers the widest range of heat tracing products for safety, comfort, and performance applications for commercial construction. Most importantly, they are the heat-trace expert and the leading full-service integrator for heat management systems. Our partnership with nVent allows the E.B. Horsman & Son staff to work with you to address all types of projects, from buildings to complex infrastructure, and optimize solutions that enhance safety, comfort and performance.

nVent RAYCHEM electric heat-tracing systems provide comfortable floor heating and reliable winter safety that can help you avoid all the above risks and more. They are easy to install and an efficient solution for every homeowner that wants to ensure the safety of their home and people.

The combination of a self-regulating heating cable and smart control system allows for dynamic management of the heating cable’s power output dependent on parameters such as ambient temperature and moisture. These will help you comply with today’s building regulations on energy savings. A complete nVent RAYCHEM system can result in energy savings of up to 80% !

Discover here how nVent RAYCHEM solutions offer you the best possible protection against the lowest temperatures.

Pipe Freeze Protection

nVent RAYCHEM pipe freeze protection systems are flexible and easy to attach to the exterior of the pipe to keep pipes from freezing, bursting, and causing water damage.

Preassembled self-regulating heating cable with 6-ft cold lead and lighted plug for small piping up to 2-1/2 inches in diameter in dry or wet locations.

  • Voltage: 120 V with plug, in lengths of 6, 12, 18, 24, 36, 50, 75 & 100 feet; 240 V with cold lead only, in lengths of 6, 12, 18 & 24 feet
  • Control options: TC-3 outlet for 120 V only. Components: H903 application tape

Self-regulating heating cable for piping up to 6 inches in diameter for dry and wet locations. The WinterGard series of products includes WinterGard, WinterGard Plus and WinterGard Wet. See the chart on pages 6-7 for more details on each.

  • Voltage: 120 V or 240 V. Control options: AMC-F5, AMC-1A, EC-TS, SST-2
  • Components: H900 hardwire or H908 plug-in power connection kit; H903 application tape; H910 Splice/Tee kit

Self-regulating heating cable with FlexFit plug for small residential piping up to 2 inches in diameter and 50 feet in length, installed in dry locations.

  • Voltage: 120 V in lengths of 50, 100, 250, 500 ft
  • Control options: TC-3 outlet. Components: 9800 FlexFit plug kit; 9610 Application tape

Mineral insulated In-Pipe Mini is for insulated piping up to 34 feet in length; In-Pipe Miser is for insulated piping up to 240 feet in length; In-Pipe Retro 120 V is for uninsulated pipes up to 150 feet in length; and the In-Pipe Retro 240 V is for uninsulated pipes up to 250 feet in length.

  • Voltage: Mini, Miser, Retro 120 V; or Retro 240 V. Control options: Built-in controller

Cut-to-length Heating Cable System with self-regulating heating cable with either fluoropolymer or polyolefin outer jacket for piping of all sizes in dry and wet locations.

  • Voltage: 120 V or 208-277 V
  • Control options: Single or multi-circuit, integrated power distribution, energy monitoring, BMS communications
  • Components: RayClic quick connect; FTC heat shrinkable fittings

Roof & Gutter De-icing

Raychem roof & gutter de-icing systems protect roofs and gutters from ice dams, heavy snow build-up and icicles. The heating cable creates a continuous path for melted ice and snow to drain.

Raychem’s basic, reliable roof & gutter de-icing solution ranges from a simple pre-assembled plug-in kit to cut-tolength heating cables. These systems are ideal for residential or small commercial buildings in light to moderate snow load areas.

Preassembled self-regulating heating cable with 6-ft cold lead and lighted plug for small piping up to 2-1/2 inches in diameter in dry or wet locations.

  • Voltage: 120 V with plug, in lengths of 6, 12, 18, 24, 36, 50, 75 & 100 feet; 240 V with cold lead only, in lengths of 6, 12, 18 & 24 feet
  • Control options: TC-3 outlet for 120 V only. Components: H903 application tape

Self-regulating heating cable that can be cut and spliced to fit the layout of any standard or standing seam roof line with gutters up to 6 inches wide. Choosing the H908 Plug-in cord eliminates the need to hardwire, thus reduces installation costs.

  • Voltage: 120 V or 240 V
  • Control and sensor options: PD-Pro and GF-Pro, LCD-8, CIT-1, GIT-1
  • Components: H900 hardwire or H908 plug-in power connection kit; H913/H914 roof clips; H915 downspout hanger; H910 Splice/Tee kit

Surface Snow Metling

Raychem surface snow melting systems keep ramps, access ways and footpaths free of snow and ice.

Our product range allows you to choose the right solution for your application and budget. Our self-regulating system for concrete surfaces and pavers reduces heat output automatically as the pavement warms and is ideal for smaller areas.

Self-regulating heating cable for surface snow melting and anti-icing in concrete pavement.

  • Voltage: 208 V; 240 V; 277 V
  • Control options: Single or multi-circuit, integrated power distribution, energy monitoring, BMS communications
  • Components: EMK heat shrinkable fittings

Need help selecting the most suitable heating solution for your home?

Talk to one of our staff and they will recommend the nVent RAYCHEM heating product that best suits your needs. Act now before the harsh winter arrives.

Transforming Lighting at Canadian College Surrey Campus with Mac’s II Agencies

From enhanced energy efficiency to modern design, see how this project is setting a new standard in campus

Liteline Recessed Downlights & Colour Selection

LED lighting options come in a spectrum of hues known as colour temperatures. This correlates to how warm (yellowish) or cool (bluish) the light

How to Prevent Industrial and Commercial Power Surges